BTQZR - HOUGHTO-SAFE 273

  • MSDS: BTQZR
  • Manufacturer: E F HOUGHTON AND CO
  • Product Name: HOUGHTO-SAFE 273
  • National Stock Number: 9150-01-080-5962
Product Identification

Product ID:HOUGHTO-SAFE 273
MSDS Date:10/13/1992
FSC:9150
NIIN:01-080-5962
MSDS Number: BTQZR

Responsible Party
E F HOUGHTON & CO
MADISON AND VAN BUREN AVE
VALLEY FORGE, PA 19482
US

Emergency Phone: 215-666-4105, CHEMTREC 800-424-9300

Info Phone: 215-666-4105

Preparer: ROBERT E. WILLIAMS

Cage: 73227

Contractor
HOUGHTON INTERNATIONAL INC
930 VALLEY FORGE, PA 19482-0930 US

Telephone: 610-666-4105

Cage: 73277

Ingredients

ETHYLENE GLYCOL (SARA 313) (CERCLA)

CAS: 107-21-1

RTECS: KW2975000

Fraction By Weight: 30-60%

ACGIH TLV: C 50 PPM,VAPOR; 9495

EPA Report Quantity: 1 LB

DOT Report Quantity: 1 LB


2-DIETHYLAMINOETHANOL

CAS: 100-37-8

RTECS: KK5075000

Fraction By Weight: <1%

OSHA PEL S, 10 PPM

ACGIH TLV: S, 2 PPM; 9495

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION OF MISTS IN EXCESS
OF TLV MAY CAUSE IRRITATION OF UPPER RESPIRATORY TRACT. CONTACT MAY
CAUSE IRRITATION OF SKIN AND EYES. INGESTION MAY BE HARMFUL; HAS
CAUSED BIRTH DEFECTS IN LAB AN IMALS. CHRONIC: NONE SPECIFIED BY
MANUFACTURER.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INGESTION-SWALLOWING LARGE AMOUNTS OF ETHYLENE
GLYCOL HAS CAUSED BIRTH DEFECTS IN LABORATORY ANIMALS.
Medical Cond Aggravated by Exposure:PERSONS WITH CHRONIC RESPIRATORY
DISEASE MAY SHOW INCREASED SYMPTOMS DUE TO IRRITATION.

First Aid

First Aid:INHALATION-REMOVE TO SOURCE OF FRESH AIR. SKIN-WASH WITH SOAP
AND WATER. EYES-FLUSH WITH WATER 15 MINUTES; CONSULT PHYSICIAN.
INGESTION-INDUCE VOMITING; CONSULT PHYSICIAN.

Fire Fighting

Extinguishing Media:PRODUCT IS A FIRE RESISTANT FLUID; NOT FLAMMABLE AS
USED. USE WATER, CARBON DIOXIDE, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:DLA-HMIS: WEAR SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:FLUSH AREA WITH WATER FOR SMALL QUANTITIES;
FOR LARGE QUANTITIES, DIKE TO CONTAIN AND EITHER REUSE OR DISPOSE
OF DEPENDING ON CONDITION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID CONTACT WITH STRONG OXIDIZERS.
AVOID INGESTION.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:REQUIRED ONLY IF TLV IS EXCEEDED.
Ventilation:EXHAUST TYPE IF MISTING; OTHERWISE GENERAL TYPE IS
SATISFACTORY.
Protective Gloves:RUBBER IF SKIN IS SENSITIVE.
Eye Protection:GOGGLES RECOMMENDED.
Other Protective Equipment:NOT REQUIRED.
Work Hygienic Practices:AVOID INGESTION.
Supplemental Safety and Health
CERCLA: NONE; RCRA-NONE; SARA III TITLE 313: 35% ETHYLENE GLYCOL, CAS#
107-21-1; MICHIGAN CRITICAL MATERIALS REGISTER; NONE; HAZARDOUS
WASTE MANAGEMENT ACT: NONE. MSDS PRESENTED BY CAGE 73277 FOR CONT
RACT SP0451-96-D0045.

Chemical Properties

HCC:V6
Boiling Pt:B.P. Text:215F,102C
Vapor Pres:AS WATER
Vapor Density:AS WATER
Spec Gravity:1.08
pH:9.5
Evaporation Rate & Reference:AS WATER
Solubility in Water:COMPLETE
Appearance and Odor:RED FLUID, SLIGHT AMMONIACAL ODOR.
Percent Volatiles by Volume:30-60

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL: OXIDES OF CARBON AND
NITROGEN.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:PROCESS THROUGH SEWAGE OR WASTE DISPOSAL SYSTEM
WHICH PROVIDES BIOLOGICAL OXIDATION. (IF WATER CONTENT IS BELOW
35%, MATERIAL MAY BE BURNED WITH FUEL OIL.)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.